<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.0 20120330//EN" "JATS-journalpublishing1.dtd">
<article article-type="abstract" dtd-version="1.0" xml:lang="en" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">CC</journal-id>
<journal-id journal-id-type="nlm-ta">Cardiol Croat</journal-id>
<journal-title-group>
<journal-title>Cardiologia Croatica</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Cardiol. Croat.</abbrev-journal-title>
</journal-title-group>
<issn pub-type="ppub">1848-543X</issn>
<issn pub-type="epub">1848-5448</issn>
<publisher><publisher-name>Croatian Cardiac Society</publisher-name></publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">CC_10_3-4_93-94</article-id>
<article-id pub-id-type="doi">10.15836/ccar.2015.93</article-id>
<article-categories><subj-group subj-group-type="heading"><subject>Abstract</subject></subj-group>
</article-categories>
<title-group>
<article-title>Three-dimensional echocardiographic diagnosis of intracardiac masses</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">http://orcid.org/0000-0003-0064-9128</contrib-id><name><surname>Vincelj</surname><given-names>Josip</given-names></name></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">http://orcid.org/0000-0002-7349-6137</contrib-id><name><surname>Jurinjak</surname><given-names>Sandra Jaksic</given-names></name></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">http://orcid.org/0000-0001-9912-2179</contrib-id><name><surname>Udovicic</surname><given-names>Mario</given-names></name></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">http://orcid.org/0000-0001-9473-2517</contrib-id><name><surname>Rudan</surname><given-names>Diana</given-names></name></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">http://orcid.org/0000-0003-4351-1102</contrib-id><name><surname>Stipcevic</surname><given-names>Mira</given-names></name></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">http://orcid.org/0000-0003-0773-4720</contrib-id><name><surname>Sicaja</surname><given-names>Mario</given-names></name></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid">http://orcid.org/0000-0002-4462-8647</contrib-id><name><surname>Vuksanovic</surname><given-names>Ilko</given-names></name></contrib>
<aff id="aff1">Dubrava University Hospital, Zagreb, <country>Croatia</country></aff>
</contrib-group>
<author-notes>
<corresp id="cor1">Address for correspondence: Josip Vincelj, Klinicka bolnica Dubrava, Avenija Gojka Suska 6, HR-10000 Zagreb, Croatia. Phone: +385-1-2902-444. E-mail: <email xlink:href="jvincelj@kbd.hr">jvincelj@kbd.hr</email></corresp></author-notes>
<pub-date pub-type="ppub"><month>05</month><year>2015</year></pub-date>
<volume>10</volume>
<issue>3-4</issue>
<fpage>93</fpage>
<lpage>94</lpage>
<history>
<date date-type="received"><day>31</day><month>03</month><year>2015</year></date><date date-type="accepted"><day>20</day><month>04</month><year>2015</year></date>
</history>
<permissions>
<copyright-year>2015</copyright-year>
<copyright-holder>Croatian Cardiac Society</copyright-holder>
</permissions>
<kwd-group kwd-group-type="author"><title>Keywords: </title><kwd>three-dimensional echocardiography</kwd><kwd>cardiac imaging</kwd><kwd>cardiac tumor</kwd><kwd>vegetation</kwd><kwd>intracardiac masses</kwd></kwd-group>
</article-meta>
</front>
<body>
<p>Echocardiography is a fundamentally important procedure for the evaluation of intracardiac masses, and can reliably identify mass location, shape size, attachment and mobility. Intracardiac masses can easily be detected by transesophageal echocardiography (TEE). Detection of intracardiac masses often represents a difficulty for transthoracic echocardiography (TTE) due to its smaller dimension or location in the left atrial appendage or the right atrium that cannot be adequately analysed by this technique. Diagnostic problems also occur in same patients with a poor &#x201E;echo window&#x201C; and in patients on mechanical ventilatory support. Echocardiography can usually distinguish between the three principal intracardiac masses: thrombus, tumor and vegetation. Three-dimensional (3D) echocardiography provides better understanding and assessment of intracardial masses than 2D echocardiography, improves the diagnostic capabilities of cardiac echocardiography in the assessment of the location, composition, size, and relationship to adjacent structures of intracardiac masses. (<xref ref-type="bibr" rid="r1"><italic>1</italic></xref>-<xref ref-type="bibr" rid="r4"><italic>4</italic></xref>)</p>
<p>Imaging plays a pivotal role in the diagnosis and surgical planning of cardiac masses treatment. Clinical features, such as patient age, location, and imaging characteristics of the mass will determine the likely differential diagnosis. Thrombi are formed within heart chambers due to trauma, endocarditis, myocardial infarction, dilated cardiomyopathy, mitral stenosis and atrial fibrillation, polycythaemia, thrombocytosis and systemic lupus erythematosus. Thrombi are more commonly found in left-sided heart chambers than in the right (<xref ref-type="fig" rid="f1">Figure 1</xref> and <xref ref-type="fig" rid="f2">Figure 2</xref>). Cardiac tumors are found in 0.001% to 0.28% of cases in pathoanatomic studies. Primary tumors are far less common than metastatic tumors in the heart, and benign primary cardiac tumors occur more frequently. Approximately 75% of cardiac tumors are benign, and the most common cardiac tumor is the myxoma. Myxomas are found in the atria in 90% of cases, three times more commonly in LA than in RA. Vegetations can be found on native or artificial valves and on the pacemaker or implantable cardioverter defibrillator leads (<xref ref-type="fig" rid="f3">Figure 3</xref>). 3D echocardiography has been more commonly used in diagnosis of intracardial masses with much higher specificity than 2D echocardiography. The evaluation of cardiac masses is often a challenge for cardiac imaging techniques. The traditional standby has been 2D echocardiography. Real time 3D echocardiography offers incremental value for the evaluation of intracardiac masses by providing more accurate assessment of the size and shape, their attachment and their mobility in some cases.</p>
<fig id="f1" position="float" fig-type="figure"><label>Figure 1</label><caption><p>Three-dimensional TTE showing a large left ventricle thrombus.</p></caption><graphic xlink:href="CC_10_3-4_93-94-f1"></graphic></fig>
<fig id="f2" position="float" fig-type="figure"><label>Figure 2</label><caption><p>Three-dimensional TTE showing a rihgt ventricle thrombus.</p></caption><graphic xlink:href="CC_10_3-4_93-94-f2"></graphic></fig>
<fig id="f3" position="float" fig-type="figure"><label>Figure 3</label><caption><p>Three-dimensional TEE showing a vegetation on the prosthetic mitral valve.</p></caption><graphic xlink:href="CC_10_3-4_93-94-f3"></graphic></fig>
<p>We report our experience with 3D TTE and 3D TEE for the assessment of intracardial masses. Three-dimensional echocardiography assessment od intracardial masses is feasible and could provide more valuable information than that obtained with 2D echocardiography. We presented LV and RV thrombus, LAA thrombus, LA myxoma and vegetation on native and prosthetic mitral valve diagnosed by 3D echocardiography.</p>
</body>
<back>
<ref-list>
<title>Literature</title>
<ref id="r1"><label>1</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Buckley</surname><given-names>O</given-names></name><name><surname>Madan</surname><given-names>R</given-names></name><name><surname>Kwong</surname><given-names>R</given-names></name><name><surname>Rybicki</surname><given-names>FJ</given-names></name><name><surname>Hunsaker</surname><given-names>A</given-names></name></person-group>. <article-title>Cardiac masses, part 1: Imaging strategies and technical considerations.</article-title> <source>AJR Am J Roentgenol</source>. <year>2011</year>;<volume>197</volume>(<issue>5</issue>):<fpage>W837-41</fpage>. <pub-id pub-id-type="doi">10.2214/AJR.10.7260</pub-id><pub-id pub-id-type="pmid">22021530</pub-id></mixed-citation></ref>
<ref id="r2"><label>2</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Zaragoza-Macias</surname><given-names>E</given-names></name><name><surname>Chen</surname><given-names>MA</given-names></name><name><surname>Gill</surname><given-names>EA</given-names></name></person-group>. <article-title>Real time three-dimensional echocardiography evaluation of intracardiac masses.</article-title> <source>Echocardiography</source>. <year>2012</year>;<volume>29</volume>(<issue>2</issue>):<fpage>207</fpage>&#x2013;<lpage>19</lpage>. <pub-id pub-id-type="doi">10.1111/j.1540-8175.2011.01627.x</pub-id><pub-id pub-id-type="pmid">22283202</pub-id></mixed-citation></ref>
<ref id="r3"><label>3</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Pepi</surname><given-names>M</given-names></name><name><surname>Evangelista</surname><given-names>A</given-names></name><name><surname>Nihoyannopoulos</surname><given-names>P</given-names></name><name><surname>Flachskampf</surname><given-names>FA</given-names></name><name><surname>Athanassopoulos</surname><given-names>G</given-names></name><name><surname>Colonna</surname><given-names>P</given-names></name><etal/></person-group> <article-title>European Association of Echocardiography. Recommendations for echocardiography use in the diagnosis and management of cardiac sources of embolism: European Association of Echocardiography (EAE) (a registered branch of the ESC).</article-title> <source>Eur J Echocardiogr</source>. <year>2010</year>;<volume>11</volume>(<issue>6</issue>):<fpage>461</fpage>&#x2013;<lpage>76</lpage>. <pub-id pub-id-type="doi">10.1093/ejechocard/jeq045</pub-id><pub-id pub-id-type="pmid">20702884</pub-id></mixed-citation></ref>
<ref id="r4"><label>4</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Biocic</surname><given-names>S</given-names></name><name><surname>Vincelj</surname><given-names>J</given-names></name><name><surname>Durasevic</surname><given-names>Z</given-names></name><name><surname>Sikic Vagic</surname><given-names>J</given-names></name></person-group>. <article-title>Ehokardiografija u odre&#x0111;ivanju izvorista embolije. Acta med.</article-title> <source>Croat</source>. <year>2001</year>;<volume>55</volume> <supplement>Suppl 3</supplement>:<fpage>75</fpage>&#x2013;<lpage>8</lpage>.</mixed-citation></ref>
</ref-list>
</back>
</article>