<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.0 20120330//EN" "JATS-journalpublishing1.dtd">
<article article-type="abstract" dtd-version="1.0" xml:lang="en" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">CC</journal-id>
<journal-id journal-id-type="nlm-ta">Cardiol Croat</journal-id>
<journal-title-group>
<journal-title>Cardiologia Croatica</journal-title>
<abbrev-journal-title abbrev-type="pubmed">Cardiol. Croat.</abbrev-journal-title>
</journal-title-group>
<issn pub-type="ppub">1848-543X</issn>
<issn pub-type="epub">1848-5448</issn>
<publisher><publisher-name>Croatian Cardiac Society</publisher-name></publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">CC 2021 16_5-6_205</article-id>
<article-id pub-id-type="doi">10.15836/ccar2021.205</article-id>
<article-categories><subj-group subj-group-type="heading"><subject>Extended Abstract</subject></subj-group>
</article-categories>
<title-group>
<article-title>Mechanical dispersion: are we one step closer to a more reliable risk prediction of sudden cardiac death</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0003-3630-0374</contrib-id><name><surname>Matana</surname><given-names>Ante</given-names></name></contrib>
<contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid">https://orcid.org/0000-0001-9415-9618</contrib-id><name><surname>Zaninovi&#x0107; Jurjevi&#x0107;</surname><given-names>Teodora</given-names></name><xref ref-type="corresp" rid="cor1">*</xref></contrib>
<aff id="aff1"><institution content-type="dept">University of Rijeka, Faculty of Medicine</institution>, <institution>University Hospital Centre Rijeka</institution>, <addr-line>Rijeka</addr-line>, <country>Croatia</country></aff>
</contrib-group>
<author-notes>
<corresp id="cor1"><label>*</label>ADDRESS FOR CORRESPONDENCE: Teodora Zaninovi&#x0107; Jurjevi&#x0107;, Klini&#x010D;ki bolni&#x010D;ki centar Rijeka, Tome Stri&#x017E;i&#x0107;a 3, HR-51000 Rijeka, Croatia. / Phone: + 385-98-320-768 / E-mail: <email xlink:href="teodorazj@gmail.com">teodorazj@gmail.com</email></corresp></author-notes>
<pub-date pub-type="epub-ppub"><month>04</month><year>2021</year></pub-date>
<volume>16</volume>
<issue>5-6</issue>
<fpage>205</fpage>
<lpage>205</lpage>
<history>
<date date-type="received"><day>28</day><month>03</month><year>2021</year></date>
<date date-type="accepted"><day>02</day><month>04</month><year>2021</year></date>
</history>
<permissions>
<copyright-year>2021</copyright-year>
<copyright-holder>Croatian Cardiac Society</copyright-holder>
</permissions>
<kwd-group kwd-group-type="author"><title>KEYWORDS: </title><kwd>mechanical dispersion</kwd><kwd>prognosis</kwd><kwd>strain echocardiography</kwd></kwd-group>
</article-meta>
</front>
<body>
<p>Cardiovascular diseases continue to be the leading cause of death in the world. A quarter of them occur by the mechanism of sudden cardiac death. Current criteria for identifying high-risk patients are unreliable and misclassify most at-risk patients as a low-risk group. Several studies in the last ten years confirmed the usefulness of mechanical dispersion in differentiating patients with high versus low risk for sudden cardiac death. Mechanical dispersion is a consequence of slow and inhomogeneous conduction of electrical impulse in the scar border zone, resulting in inhomogeneous myocardial activation and heterogeneity of myocardial contraction. This is why mechanical dispersion is in fact an expression of electrical dispersion, but unlike electrical dispersion it can be measured more easily and more reliably. It is obtained by speckle tracking echocardiography and is expressed as the standard deviation of all time intervals to the maximum myocardial shortening. Several studies have shown this method is significantly more reliable than the left ventricular ejection fraction and the left ventricular global longitudinal strain in differentiating high-risk from low-risk patients. Best results have been obtained in conditions characterized by fibrosis and/or scarring of the myocardium, such as in patients with myocardial infarction, hypertrophic, dilated and arrhythmogenic cardiomyopathy, some valvular heart diseases and heart failure. Mechanical dispersion could be useful as a risk stratification tool in identifying patients that can optimally benefit from the prophylactic treatment. (<xref ref-type="bibr" rid="r1"><italic>1</italic></xref>-<xref ref-type="bibr" rid="r3"><italic>3</italic></xref>) Although promising, for now this method is not listed in the current guidelines for the prevention of sudden cardiac death. It remains to be seen whether the new ones will bring changes in this field.</p>
</body>
<back>
<ref-list>
<title>LITERATURE</title>
<ref id="r1"><label>1</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Haugaa</surname><given-names>KH</given-names></name><name><surname>Grenne</surname><given-names>BL</given-names></name><name><surname>Eek</surname><given-names>CH</given-names></name><name><surname>Ersb&#x00F8;ll</surname><given-names>M</given-names></name><name><surname>Valeur</surname><given-names>N</given-names></name><name><surname>Svendsen</surname><given-names>JH</given-names></name><etal/></person-group> <article-title>Strain echocardiography improves risk prediction of ventricular arrhythmias after myocardial infarction.</article-title> <source>JACC Cardiovasc Imaging</source>. <year>2013</year> August;<volume>6</volume>(<issue>8</issue>):<fpage>841</fpage>&#x2013;<lpage>50</lpage>. <pub-id pub-id-type="doi">10.1016/j.jcmg.2013.03.005</pub-id><pub-id pub-id-type="pmid">23850251</pub-id></mixed-citation></ref>
<ref id="r2"><label>2</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Candan</surname><given-names>O</given-names></name><name><surname>Gecmen</surname><given-names>C</given-names></name><name><surname>Bayam</surname><given-names>E</given-names></name><name><surname>Guner</surname><given-names>A</given-names></name><name><surname>Celik</surname><given-names>M</given-names></name><name><surname>Do&#x011F;an</surname><given-names>C</given-names></name></person-group>. <article-title>Mechanical dispersion and global longitudinal strain by speckle tracking echocardiography: Predictors of appropriate implantable cardioverter defibrillator therapy in hypertrophic cardiomyopathy.</article-title> <source>Echocardiography</source>. <year>2017</year> June;<volume>34</volume>(<issue>6</issue>):<fpage>835</fpage>&#x2013;<lpage>42</lpage>. <pub-id pub-id-type="doi">10.1111/echo.13547</pub-id><pub-id pub-id-type="pmid">28444773</pub-id></mixed-citation></ref>
<ref id="r3"><label>3</label><mixed-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Prihadi</surname><given-names>EA</given-names></name><name><surname>Vollema</surname><given-names>EM</given-names></name><name><surname>Ng</surname><given-names>ACT</given-names></name><name><surname>Ajmone Marsan</surname><given-names>N</given-names></name><name><surname>Bax</surname><given-names>JJ</given-names></name><name><surname>Delgado</surname><given-names>V</given-names></name></person-group>. <article-title>Determinants and prognostic implications of left ventricular mechanical dispersion in aortic stenosis.</article-title> <source>Eur Heart J Cardiovasc Imaging</source>. <year>2019</year> July 1;<volume>20</volume>(<issue>7</issue>):<fpage>740</fpage>&#x2013;<lpage>8</lpage>. <pub-id pub-id-type="doi">10.1093/ehjci/jez004</pub-id><pub-id pub-id-type="pmid">30726895</pub-id></mixed-citation></ref>
</ref-list>
</back>
</article>